Series 3000Model R-197AVAudio/Video Relay PanelWith Ethernet InterfaceInstruction ManualCATV Switching and Control EAS585-765-2254 fax 585-765-93301
Ethernet Interface SetupOn the CD included with the unit is a program entitled Netburner IPSetup V2.0.After ensuring that the R-197AV to be set up is
You may now use the included Setup on the server IF you are directly connected to the unit.If you are connected to the unit through a network, you mus
To set the parameters in the R197A, click on ‘Setup”, and the following screen will appear:12
Select ‘Password’, the follwing screen appears:The default password for the R197A is r197set, all lower case.A User Name is not required.13
After clicking ‘Log In’, the following screen appears:Note that you may change, and enable if desired, the Control Password,and change the Setup Passw
Select the Switch link, we see this page. Note we are allowed – but not required –To set labels for the device and each switch. We may also configure
Note also, that you may select the frequency of refreshing the switch control page on thisSetup page.16
Changing network settings after the initial setting of the IP address, it isaccomplished here. This page is reached by clicking on the ‘Network’ tab
After completing the setup for the device, and installing it in the system, the operator brings upthe Switch Control page, and sees the screen below.N
EAS Switching(VIA DAS DEC)19
Table of ContentsSpecifications 3General Description 4General Instructions 6Applications General Switching Audio 7 Connections 9 Ethernet Interfac
Configuring the DASDECEach switch of the R197AV is network controlled by the DASDEC over a TCP/IP (Ethernet)connection. Each of the R197AV program swi
6. If using the 2nd network interface select the Static (Manually Configure) radio button,otherwise continue to Step 7.7. In the Manual Config Opt
15. The Name box will default to NETGPIO x where “x” is the next number in the sequence.You can leave the current name or type a different name for th
23. Select the second2active (enabled) station in the Select Station ConfigurationInterfaceusing the pull down. (Note: Active (enabled) stations are i
26. In the Forwarding Audio Output Devices box click on Aux1 Audio Output.27. Click Submit Selection Settings button at the bottom of the table (See F
Specifications Power Requirement100-240VAC +/- 2%, 50/60Hzsupplies +12V DC @ <300mA(UL approved wall supply included.) Control InputsContact Clos
General DescriptionIn its simplest form, the R-197AV is nothing more than a multi-contact relay capable of switch-ing away from signal A and connectin
Front Panel ViewRear Panel ViewSection View5
General InstructionsMounting:The R-197AV requires a minimum of 1.75 vertical inches of space in a standard 19” wide EIAequipment rack. Slide the unit
AppplicationsGeneral SwitchingControl by TimeThe R-197AV can be directly connected to Monroe R153 program timers so that programsignals can be switche
This diagram shows the inputs/outputs of the R197A and the R197AV.8
This diagram shows, more specifically, the input and outputs connec-tions for the R197A and R197AV.9