Monroe-electronics R199 Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Specifications
Power Requirement
100-240VAC+/-2%,50/60Hz
supplies+12VDC@<300mA
(ULapprovedwallsupplyincluded.)
Timed Switching
Clockaccuracy<+/-1second/week
Control Inputs
ContactClosuretoGNDorlogicinput
AbsoluteMaximumInputVoltage+12VDC
LogicalHighInputVoltage+7VDC
LogicalLowInputVoltage+2VDC
Ethernet Input
10/100baseTwithEmbeddedServer
Controlviawebbrowser
Audio Relays Contact Rating:
30VDCmax;1Amax
Audio Connections
BalancedStereo,ScrewTerminals
Video Relays Contact Rating:
+60dBmVRF,0to1GHz
Video Connectors:
75ohm,‘F’type
Physical
1.75”HX19”WX7”D,1RU
Weight5lbs.
Optional Redundant Power
Withadditionalsupply.
Accessories Included with Instrument
PowerSupply
Matingconnectors
MountingKit
Manual/DataSheetonCD
3
Vue de la page 2
1 2 3 4 5 6 7 8 ... 28 29

Commentaires sur ces manuels

Pas de commentaire