APNE-0016
94
Barrier requirements and recommended enclosures are shown in the tables below:
MTL Barriers and Enclosures
Number of
Channels
1
2
4
6
8
10
12
14
16
Number of Barriers
MTL 765 2 4 8 12 16 20 24 28 32
MTL 766 2 4 8 12 16 20 24 28 32
Recommended Enclosures
MT 5 1
MT 12 1
MT 24 1 1 2 2
MT 32 1 2 2
Table VI-1
Notes for MTL Systems:
Enclosures include barrier mounting hardware, tagging strips, etc. Labeled wiring
ducts are included with MT 32.
Listed enclosures are glass-filled polycarbonate with transparent lids. They are
impact resistant, flame retardant and dustproof to IEC529:IP65.
MTL will install barriers at no charge if supplied with position (sequence) information.
"Internals" (everything that normally goes in an enclosure but no enclosure) are
available.
Vue de la page 94